Daisy Cooper Portrait Daisy Cooper (St Albans) (LD)
- Hansard - -

Q I have two interlinked issues. One is about the number of assessors needed; we have received some evidence that suggests there are around 400 third-party registered fire risk assessors and potentially around 400 APQC independent assessors, but there is nobody putting a number on the assessors that might be needed.

The first question is whether you have any estimates, because we know roughly where we are at the moment and where we need to get to. I was pleased to hear you say that you would welcome a register of assessors, but the interlinked issue is how we train those people. We have had differing evidence. Some suggests there should be a fast-track training, or different levels of assessment, and other evidence suggests that we should not have fast-track training because it can lead to problems. I would welcome your views on both questions: how many people do we need overall, and does there need to be comprehensive training for everybody, or would you take a differentiated view?

Dan Daly: I do not think I can give you a number on how many we need overall, because there is a bit of work to be done before that. This speaks back to the risk-based approach. If we look at the work we are doing with the building safety regulator and the ideas going forward about the level of competency to interact with buildings of different complexity and risk, we could apply a similar staged approach to how we look at the buildings to which the legislation needs to be applied. Picking up those most at risk will allow time for training to come through, and development of people to support the wider piece of work, while ensuring that the effort is focused on the buildings that we would see as highest risk.

There is further work that we need to do as a service overall on understanding what risk looks like. We have a historical risk matrix that informs the regularity with which we inspect buildings; that was based on good evidence at the time, but we have a richer understanding of risk now. We understand vulnerabilities, behaviours and lifestyles that have an equal impact on the likelihood of fire, and therefore the settings that those people may be living in. It helps us understand risk in a totally different way—understanding that this is not just our opportunity to fix high-rise living but is about the wider built environment. It is an opportunity to understand risk in a much more holistic way and ensure we are applying more rigorous inspections to those higher-risk premises, and an appropriate level of inspection to those lower down the risk register, so to speak.

Andy Slaughter Portrait Andy Slaughter (Hammersmith) (Lab)
- Hansard - - - Excerpts

Q I had a couple of questions, mainly for Mr Daly. Could I just clarify something from your opening statement? Is it your view that this Bill does not add in new types of premises or new responsibilities but is simply clarifying what should already be happening?

Dan Daly: That is certainly my understanding.

--- Later in debate ---
Daisy Cooper Portrait Daisy Cooper
- Hansard - -

Q Mr Wrack, in your written evidence, you say that

“the impact assessment ‘does not include any additional enforcement costs’”,

and you suggest that fire inspectors would need to spend

“a great deal of time and effort”

to focus on getting cases through the courts and so on. I suspect this question might be like, “How long is a piece of string?”, but in the absence of an impact assessment, can you give an estimate of your own assessment of what those additional enforcement costs might be?

Matt Wrack: I am afraid I am not able to give that. I do think that, on the question of enforcement, there have been cases of ministerial pressure to reduce the enforcement role of the fire and rescue service, which is something that Ministers need to think carefully about. Fire services have been criticised subsequently for being slow to act on their enforcement role.

The whole question of fire services’ enforcement role ties in with the more general points I have made, in that they need adequate specialist fire safety teams, and that is possibly the area, or certainly one of the areas, where we have seen the largest reductions in staffing levels, with all the knock-on concerns about training and refresher training. I am not able to answer that question directly, but I think it is very much a resource question.

Andy Slaughter Portrait Andy Slaughter
- Hansard - - - Excerpts

Q Good afternoon to you both. We have heard that this Bill is a clarifying Bill rather than one that introduces new powers. Do you agree that that is its purpose, and do you think it achieves that?

The specific point that I would like you both to address is that it appears, as there is a specific mention of “external walls” in clause 1, that the Bill is directed at what we have already seen coming out of the Grenfell inquiry in relation to external cladding and cladding systems. But lots more issues have emerged from that, such as the way that buildings are constructed or modified, means of escape, alarm systems and the processes for evacuation in that way. Do you think that they are also adequately covered in the Bill or do we need other legislation? Do you think we have the means to carry out all those matters?

Adrian Dobson: There is quite a range of questions there. Essentially, in my view, the Bill is just clarifying and pointing to some key facts, as it is not fundamentally changing the nature of the approach. I could not agree more that, although it is useful to highlight the issue of external wall construction and cladding, there are lots of other known issues in relation to fire safety. For example, the Scottish schools report talks a lot about fire compartmentation and lack of proper fire barriers. You have pointed out the issue around means of escape and evacuation strategies. To return to my earlier point, I see this as only part of the jigsaw. What we desperately need is clarification of the building regulations themselves and a stronger enforcement or competency regime around that, so that the two work together.

Matt Wrack: I see the Bill as a clarifying Bill, as has been suggested. On that level, we welcome it, with some of the amendments in particular. You highlight an important point—much of the national focus is on cladding.

There is clearly a national scandal about flammable cladding being put on to buildings, but we are aware from Grenfell and other fires that there are many other failings in fire safety in buildings, particularly with the risk of the breakdown of compartmentation. Cladding is clearly one mechanism by which that happened at Grenfell, but issues around other materials used in renovations and modifications of buildings are also relevant. If people have fire resistant walls and drill holes through them, that will clearly alter the fire resistance of the compartment. All those things need to be built into a proper fire safety regime.

I do not think the Bill addresses the question of evacuation. That is obviously a huge concern to people living in high-rise residential buildings; it is also a huge concern to firefighters, who have been trained for decades in ways to fight fires in high-rise residential buildings that are based on the construction and design of those buildings. Over the past 20 years or so, those buildings have been modified in a way that was never intended, which has altered the whole structure and fire behaviour in those buildings.

In our view, there is no simple answer to the question of evacuation. Again, we raised the question of a review of evacuation at the close of stage 1 of the Grenfell Tower inquiry. We now have Government bodies looking at reviewing the evacuation policy and saying that it might take two or three years. Firefighters were apparently supposed to decide on new strategies on the night, even though the people reviewing the policy have told us that it will take them two years or more to reach such a conclusion.

I come back to my point about a joined-up approach. We should have bodies in the British fire service that take account of the views of all professionals, take account of research and develop answers to these questions as we go along. We should be horizon-scanning. There had been fires in clad buildings elsewhere in the world. It is staggering that no one in leadership positions in the British fire service or at Government level was monitoring those and seeing what should happen to alter policy in Britain.